DC/DC Converter
TRN 3 Series, 3 Watt
•
Compact SIP package
11,9 x 7,7 x 11,0 mm
•
•
Fully regulated outputs
•
•
I/O-isolation 1‘600 VDC
•
•
Short circuit protection
•
3-year product warranty
Input Voltage range
4.5-13.2, 9-18, 18-36, 36-75 VDC
Operating temperature range
–40°C to +85°C
Designed to meet IEC/EN/UL 62368-1
(not certified)
The TRN 3 Series comprises 3 Watt fully regulated, high performance DC/DC
converters. They come in a compact cubical package of only 1.00 cm³. Full
load operation is reliable up tp 65°C environment temperature. With 1’600
VDC I/O isolation voltage, and short current protection they cover a wide range
of application when space is limited. The input of the converters is designed for
a wide voltage range (2:1) and minimum load is not required. The functional
I/O-isolation system is designed to meet IEC/EN/UL 62368-1 (not certified)
with a test voltage (60 s) of 1600 VDC.
Models
Order Code
Input Voltage
Range
TRN 3-0510
TRN 3-0511
TRN 3-0512
TRN 3-0513
TRN 3-0515
TRN 3-0521
TRN 3-0522
TRN 3-0523
TRN 3-1210
TRN 3-1211
TRN 3-1212
TRN 3-1213
TRN 3-1215
TRN 3-1221
TRN 3-1222
TRN 3-1223
TRN 3-2410
TRN 3-2411
TRN 3-2412
TRN 3-2413
TRN 3-2415
TRN 3-2421
TRN 3-2422
TRN 3-2423
TRN 3-4810
TRN 3-4811
TRN 3-4812
TRN 3-4813
TRN 3-4815
TRN 3-4821
TRN 3-4822
TRN 3-4823
www.tracopower.com
4.5 - 13.2 VDC
(9 VDC nom.)
9 - 18 VDC
(12 VDC nom.)
18 - 36 VDC
(24 VDC nom.)
36 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
+5 VDC
+12 VDC
+15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
+5 VDC
+12 VDC
+15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
+5 VDC
+12 VDC
+15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
+5 VDC
+12 VDC
+15 VDC
700 mA
600 mA
250 mA
200 mA
125 mA
300 mA
125 mA
100 mA
700 mA
600 mA
250 mA
200 mA
125 mA
300 mA
125 mA
100 mA
700 mA
600 mA
250 mA
200 mA
125 mA
300 mA
125 mA
100 mA
700 mA
600 mA
250 mA
200 mA
125 mA
300 mA
125 mA
100 mA
September 28, 2023
Vnom
Efficiency
Imax
–5 VDC
–12 VDC
–15 VDC
300 mA
125 mA
100 mA
–5 VDC
–12 VDC
–15 VDC
300 mA
125 mA
100 mA
–5 VDC
–12 VDC
–15 VDC
300 mA
125 mA
100 mA
–5 VDC
–12 VDC
–15 VDC
300 mA
125 mA
100 mA
typ.
75 %
78 %
82 %
80 %
80 %
77 %
80 %
80 %
76 %
79 %
84 %
83 %
82 %
78 %
82 %
81 %
76 %
78 %
84 %
84 %
83 %
79 %
83 %
82 %
75 %
79 %
83 %
83 %
82 %
77 %
82 %
80 %
Page 1 / 4
TRN 3 Series, 3 Watt
Input Specifications
Input Current
- At no load
9 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
9 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
9 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
9 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
Surge Voltage
Reflected Ripple Current
Recommended Input Fuse
Input Filter
75 mA typ.
40 mA typ.
20 mA typ.
12 mA typ.
15 VDC max. (1 s max.)
25 VDC max. (1 s max.)
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
100 mAp-p typ.
75 mAp-p typ.
75 mAp-p typ.
50 mAp-p typ.
1'600 mA (slow blow)
800 mA (slow blow)
500 mA (slow blow)
315 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Capacitor
Output Specifications
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
Capacitive Load
- Cross Regulation
(25% / 100% asym. load)
- 20 MHz Bandwidth
- single output
- dual output
Minimum Load
Temperature Coefficient
Start-up Time
Short Circuit Protection
Output Current Limitation
Transient Response
±1% max.
0.2% max.
0.2% max.
1% max.
1% max. (Output 1)
1% max. (Output 2)
dual output models: 5% max.
single output models:
dual output models:
single output models:
dual output models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
5 / -5 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
- Response Deviation
- Response Time
50 mVp-p typ.
4'400 µF max.
2'200 µF max.
1'000 µF max.
820 µF max.
330 µF max.
1'200 / 1'200 µF max.
520 / 520 µF max.
440 / 440 µF max.
Not required
±0.02 %/K max.
5 ms typ. / 15 ms max.
Continuous, Automatic recovery
180% typ. of Iout max.
3% typ. (25% Load Step)
500 µs typ. (25% Load Step)
Safety Specifications
Standards
- IT / Multimedia Equipment
Designed for IEC/EN/UL 62368-1 (not certified)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 28, 2023
Page 2 / 4
TRN 3 Series, 3 Watt
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
External filter proposal:
EMS Immunity
- Electrostatic Discharge
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
Ext. input component:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
1 s:
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
www.tracopower.com/overview/trn3
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
Nippon chemi-con KY 220 µF/ 100 V
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
Cooling System
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
Environment
Housing Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
- Input to Output, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
- Vibration
- Thermal Shock
95% max. (non condensing)
–40°C to +85°C
+105°C max.
–55°C to +125°C
2.5 %/K above 65°C
See application note: www.tracopower.com/overview/trn3
Natural convection (20 LFM)
100 kHz min. (PFM)
Functional Insulation
1'600 VDC
1'000 MΩ min.
75 pF max.
4'400'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
MIL-STD-810F
MIL-STD-810F
Non-conductive Plastic (UL 94 V-0 rated)
Silicone (UL 94 V-0 rated)
Copper
Nickel (0.3 - 0.9 µm)
Tin (5 - 6 µm), matte
Plastic Case
PCB Mount
THD (Through-Hole Device)
SIP5
Lead-Free Wave Soldering
260°C / 6 s max.
2.1 g
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 28, 2023
Page 3 / 4
TRN 3 Series, 3 Watt
Environmental Compliance - REACH Declaration
www.tracopower.com/info/reach-declaration.pdf
- RoHS Declaration
- SCIP Reference Number
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
c4b0b7c5-530c-496b-8e09-3d18ee29c836
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/trn3
Outline Dimensions
11.9
Pinout
(0.47)
0.5 x 0.25
7.7
3 4 5
(0.3)
1 2
3.7
bottom view
(0.15)
(0.02 x 0.01)
1.6
4.1
2.0
2.8
2x2.0
(0.08)
(0.11)
(2x0.08)
Single
Dual
1
–Vin (GND)
–Vin (GND)
2
+Vin (Vcc)
+Vin (Vcc)
3
+Vout
+Vout
4
No pin
Common
5
–Vout
–Vout
(0.43)
(0.16)
11.0
(0.06)
Pin
Dimensions in [mm], () = Inch
Tolerances: x.x ±0.5 (±0.02)
x.xx ±0.25 (±0.01)
Pin pitch tolerances ±0.25 (±0.01)
Pin dimension tolerance ±0.1 (±0.004)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 28, 2023